Λογότυπο Eταιρίας [302xX]
Πάνω Frame [668xX]
 
Heat pump DHW
 
 
Central Vacuum
 
Enerbis Solar
 
Water mixer
 

 

    

 
bleft6
 
 

MAXA CALIDO 300-D

Model: 1144-006

Manufacturer: ADVANTIX spa

Παράδοση σε 4 - 10 ημέρες

 

Price: 2.710,00€ 

Free Installments:
Month Installment:

The MAXA CALIDO heat pump, is delivered complete for the direct connection to the domestic hot water installation and it is ideal for residential as well as for light commecial applications such as hair salons, cafeterias or restaurants e.t.c where there is increased need for hot water.

The All-In-One heat pumps are installed very easily as they do not need any special components for their connection to the domestic hot water system. Also, they can be easily disconnected form one instalaltion and they can be transferred without any difficulty to any new location.

It is suitable for heating or cooling operation and it can be connected in casccade (master-slave mode) to acheive even larger heating or cooling capacities.

Performance
Heating capacity (1) Watt 1870 (+1200*)
Absorbed power (1) Watt 503 (+1200*)
Hot water tank capacity Lit 273
C.O.P. W/W 3,72
Energy efficiency (2)   A
Maximum water temperature °C 75°C *
Minimum start water temperature °C 10°C
Operation limits °C Min: -10°C  / Max: +43°C
Refrigerant R134a 920 gr
Technical Characteristics
Power / Frequency / Phases V/Hz/ph 220-240/1/50
Absorbed current (1) A 2,23 (+5,2*) 
Air flow m3/hr 450
Duct diameter (3) mm 177
Allowed pressure bar 10
Auxiliary heater kW 1,2
Solar exchanger surface m2 1,2
Auxiliary exchanger surface m2 0,8
Protection   IPX1
Sound level (4) dB(A) 46
Dimensions and weight
Dimensions (Dia.x H) mm Φ654 x 1888
Packing Dimensions mm 700 x 700 x 2010
Weight Kgr 129,5
Weight with full water Kgr 402,5

 

(*) Related to the supplementary e-heater. During disinfection, the water temp is shifted up to 70°C by auxiliary electrical heater

(1) Capacity and power input based on the following conditions: ambient temperature 20°C,water temperature from 15°C to 55°C

(2) Heating energy efficiency class, load profile: L. Refers to indoor air (+20°C). Reg. UE 812/2013

(3) The pipeline can be reduced from 177 to 160 mm by a reduction inserted into the end of the pipeline.

(4) Measured in free field at 1 m from the unit according to EN 12102 standard.