Heat pump MAXA i-HWAK/WP/V4 14 (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 5,50 - 13,76 - 15,10*
Absorbed power kW 3,20
C.O.P. W/W 4,30
Heating capacity  A7°/6°C - W45°C kW 5,30 - 13,55 - 14,90*
Absorbed power kW 4,04
C.O.P. W/W 3,35
S.C.O.P. W/W4 4,01
Cooling capacity        W23°- 18°C - A35°C kW 6,70 - 13,80 - 15,20*
Absorbed power kW 2,93
E.E.R W/W 4,72
Cooling capacity        W7°- 12°C - A35°C kW 5,30 - 11,46 - 12,05*
Absorbed power kW 3,70
E.E.R W/W 3,10
S.E.E.R.   4,51
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum operation current A 32,8
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 2 x 0,15
Circulator power W 140
Water flow m³/hr 2,37
Pump head kPa 63,4
Water connection inch 1
Noise level    
Noise level dB(A) 65,5
Dimensions and weights    
Dimensions (LxDxH) mm 1060 x 455 x 1405
Weight Kgr 119

5.950,00€ 

SolarBox - 2

SolarBox - 2 with two thermodynamic solar panels, including::

  • Two thermodynamic panels
  • The solar box
  • Pre-charged
  • Rubber feet
  • Quick fixation kit (type "L" brackets)
  • Flare valves
  • Hydraulic filter
Performance    
Maximum thermal power (med./max.) Watt 2.800 / 4.550
Maximum consumed power (med./max.) Watt 595 / 890
Energy Class (Erp)   Α
Maximum water temperature °C 55°C
Cooling media Type / gr R134a / 1.000
Technical charakteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum working pressure bar 7
Therm. Unit Input | Output Connections (thread) inch 1/2 | 1/2
Therm. Panel Input | Output Connections (thread) nch 3/8 | 1/4
Sound level    
Sound level dB(A)  
Dimensions and weights    
Dimensions (LxDxH) (Solar Box) mm 367 x 318 x 438
Weight (Solar Box / Panel) Kgr 23,5 / 2x8

2.765,00€ 

Heat pump MAXA i-HWAK/WP/V4 08 (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 3,54 - 8,01 - 8,81*
Absorbed power kW 1,85
C.O.P. W/W 4,33
Heating capacity  A7°/6°C - W45°C kW 2,85 - 7,92 - 8,71*
Absorbed power kW 2,40
C.O.P. W/W 3,31
S.C.O.P. W/W 3,83
Cooling capacity        W23°- 18°C - A35°C kW 4,65 - 8,52 - 9,12*
Absorbed power kW 2,18
E.E.R W/W 3,91
Cooling capacity        W7°- 12°C - A35°C kW 2,95 - 6,12 - 6,73*
Absorbed power kW 2,11
E.E.R W/W 2,90
S.E.E.R.   3,61
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum operation current A 21,2
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 1 x 0,15
Circulator power W 45
Water flow m³/hr 1,38
Pump head kPa 34,5
Water connection inch 1
Noise level    
Noise level dB(A) 62,5
Dimensions and weights    
Dimensions (LxDxH) mm 925 x 380 x 785
Weight Kgr 63,4

4.050,00€ 

Heat pump MAXA i-HWAK/WP/V4 06 (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 2,76 - 6,57 - 7,23*
Absorbed power kW 1,47
C.O.P. W/W 4,47
Heating capacity  A7°/6°C - W45°C kW 2,24 - 6,15 - 6,76*
Absorbed power kW 1,83
C.O.P. W/W 3,36
S.C.O.P. W/W 3,84
Cooling capacity        W23°- 18°C - A35°C kW 3,65 - 6,87 - 7,56*
Absorbed power kW 1,69
E.E.R W/W 4,06
Cooling capacity        W7°- 12°C - A35°C kW 2,30 - 5,07 - 5,58*
Absorbed power kW 1,74
E.E.R W/W 2,91
S.E.E.R.   3,59
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum operation current A 14,4
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 1 x 0,15
Circulator power W 45
Water flow m³/hr 1,13
Pump head kPa 44,6
Water connection inch 1
Noise level    
Noise level dB(A) 62,0
Dimensions and weights    
Dimensions (LxDxH) mm 925 x 380 x 785
Weight Kgr 63,4

3.750,00€ 

Heat pump MAXA i-HWAK/WP/V4 10 (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 4,69 - 10,0 - 10,8*
Absorbed power kW 2,26
C.O.P. W/W 4,43
Heating capacity  A7°/6°C - W45°C kW 3,90 - 9,51 - 10,3*
Absorbed power kW 2,74
C.O.P. W/W 3,47
S.C.O.P. W/W 4,24
Cooling capacity        W23°- 18°C - A35°C kW 5,40 - 10,0 - 11,35*
Absorbed power kW 2,26
E.E.R W/W 4,43
Cooling capacity        W7°- 12°C - A35°C kW 3,27 - 7,56 - 8,83*
Absorbed power kW 2,43
E.E.R W/W 3,11
S.E.E.R.   4,63
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum operation current A 22,4
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 1 x 0,15
Circulator power W 60
Water flow m³/hr 1,72
Pump head kPa 39,4
Water connection inch 1
Noise level    
Noise level dB(A) 63,0
Dimensions and weights    
Dimensions (LxDxH) mm 1047 x 465 x 913
Weight Kgr 95,5

4.900,00€ 

SolarBox - 1

SolarBox - 1 with one thermodynamic solar panel, including::

  • One thermodynamic panel
  • The solar box
  • Pre-charged
  • Rubber feet
  • Quick fixation kit (type "L" brackets)
  • Flare valves
  • Hydraulic filter
Performance    
Maximum thermal power (med./max.) Watt 1.690 / 2.900
Maximum consumed power (med./max.) Watt 390 / 550
Energy Class (Erp)   Α
Maximum water temperature °C 55°C
Cooling media Type / gr R134a / 800
Technical charakteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum working pressure bar 7
Therm. Unit Input | Output Connections (thread) inch 1/2 | 1/2
Therm. Panel Input | Output Connections (thread) nch 3/8 | 1/4
Sound level    
Sound level dB(A)  
Dimensions and weights    
Dimensions (LxDxH) (Solar Box) mm 367 x 318 x 438
Weight (Solar Box / Panel) Kgr 23,5 / 8

2.193,00€ 

Heat pump MAXA i-HWAK/WP/V4 14T (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 5,50 - 13,76 - 15,10*
Absorbed power kW 3,20
C.O.P. W/W 4,30
Heating capacity  A7°/6°C - W45°C kW 5,30 - 13,55 - 14,90*
Absorbed power kW 4,04
C.O.P. W/W 3,35
S.C.O.P. W/W4 4,01
Cooling capacity        W23°- 18°C - A35°C kW 6,70 - 13,80 - 15,20*
Absorbed power kW 2,93
E.E.R W/W 4,72
Cooling capacity        W7°- 12°C - A35°C kW 5,30 - 11,46 - 12,05*
Absorbed power kW 3,70
E.E.R W/W 3,10
S.E.E.R.   4,51
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 480/3/50
Maximum operation current A 10,9
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 2 x 0,15
Circulator power W 140
Water flow m³/hr 2,37
Pump head kPa 63,4
Water connection inch 1
Noise level    
Noise level dB(A) 65,5
Dimensions and weights    
Dimensions (LxDxH) mm 1060 x 455 x 1405
Weight Kgr 119

6.100,00€ 

Heat pump MAXA i-HWAK/WP/V4 12 (monoblock)

The MAXA 3D inverter heat pump of i-HWAK/WP/V4 series and monoblock type, is delivered complete for the direct connection to the heating or cooling installation or the domestic hot water production system and it is ideal for the new building isntallations as well as for the replacement of the existing heating boiler in old buildings.

The heat pump is delivered complete with the following components included within the cabinet::

  • Pump with high efficiency brushless circulator

  • Expansion vessel

  • Flow switch

  • Air vent

  • Pressure relief valve (6 bar), pressure gauge

  • Water valve for system charge/discharge

  • Controller for setting up the parameters of the system

Performance    
Heating capacity A7°/6°C - W35°C kW 4,69 - 12,10 - 12,70*
Absorbed power kW 2,89
C.O.P. W/W 4,19
Heating capacity  A7°/6°C - W45°C kW 3,90 - 11,30 - 12,10*
Absorbed power kW 3,32
C.O.P. W/W 3,41
S.C.O.P. W/W 4,31
Cooling capacity        W23°- 18°C - A35°C kW 5,40 - 11,90 - 13,10*
Absorbed power kW 2,65
E.E.R W/W 4,49
Cooling capacity        W7°- 12°C - A35°C kW 3,27 - 8,49 - 9,60*
Absorbed power kW 2,74
E.E.R W/W 3,10
S.E.E.R.   4,73
Energy Classification   Α++/Α+
Maximum water temperature °C 58°C / 63°C
Operation limits °C Min: -20°C  / Max: +46°C
Freon   R410a
Technical characteristics    
Voltage / Frequency / Phases V/Hz/ph 230/1/50
Maximum operation current A 26,*9
Compressor type   Twin Rotary DC Inverter
Axial fan no x kW 1 x 0,15
Circulator power W 75
Water flow m³/hr 2,08
Pump head kPa 34,2
Water connection inch 1
Noise level    
Noise level dB(A) 63,5
Dimensions and weights    
Dimensions (LxDxH) mm 1047 x 465 x 913
Weight Kgr 95,5

5.100,00€ 

With choosen: